Call 07942873686 63% Response Rate

our range

Escorts Silent Diesel Generators

Our range of products include 10 kva escorts silent diesel generator, 15 kva escorts silent diesel generator, 20 kva escorts silent diesel generator, 25 kva escorts silent diesel generator, 30 kva escorts silent diesel generator and 35 kva escorts silent diesel generator.
  • 10 KVA Escorts Silent Diesel Generator
  • 10 KVA Escorts Silent Diesel Generator
  • 10 KVA Escorts Silent Diesel Generator
10 KVA Escorts Silent Diesel Generator

10 KVA Escorts Silent Diesel Generator

Rs 2.3 Lakh  / PieceGet Best Price

Product Brochure

Power10 kVA
MaterialMS
BrandEscorts
ApplicationIndustrial
Cooling SystemLiquid Cooling
Noise LevelSilent or Soundproof
Engine ModelG12-II
Dimension1530 x 930 x 1160 mm (L x B x H)
Fuel Tank Capacity80 Liter
No Of Cylinders2
Weight655 kg
Voltage415 V
DG ModelELG 10
Rated Current43 Amps at 230 V, 14 Amps at 415 V
Brake Horsepower18 BHP
Aluminium Cable2C-25/3.5C-16 Sq. mm.
AspirationNatural
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 15 kVA Escorts Silent Diesel Generator
  • 15 kVA Escorts Silent Diesel Generator
  • 15 kVA Escorts Silent Diesel Generator
15 kVA Escorts Silent Diesel Generator

15 kVA Escorts Silent Diesel Generator

Rs 2.49 Lakh  / PieceGet Best Price

Product Brochure

Power Rating15 kVA
BrandEscorts
Cooling SystemLiquid Cooling
Fuel TypeDiesel
Engine ModelG15-II
Dimension2100 x 930 x 1400 mm (L x B x H)
Fuel Tank Capacity130 L
Rated Current66 Amp at 230 V, 21 Amp at 415 V
No Of Cylinders2
Weight700 kg
700 Kg415 V
DG ModelELG 15
Brake Horsepower23 BHP
AspirationNatural
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 20 kVA Escorts Silent Diesel Generator
  • 20 kVA Escorts Silent Diesel Generator
  • 20 kVA Escorts Silent Diesel Generator
20 kVA Escorts Silent Diesel Generator

20 kVA Escorts Silent Diesel Generator

Rs 2.95 Lakh  / PieceGet Best Price

Product Brochure

Power20 kVA
BrandEscorts
MaterialMS
ApplicationIndustrial
Cooling SystemLiquid Cooling
Noise LevelSilent or Soundproof
Engine ModelG20-II
Dimension2300 x 930 x 1400 mm (L x B x H)
Fuel Tank Capacity130 Liter
No Of Cylinders3
Dg Set ModelELG 20
Weight812 Kg
Voltage415 V
Brake Horsepower27.6 BHP
Rated Current87 Amps at 230 V, 28 Amps at 415 V
Aluminium Cable2C-50/3.5C-16 Sq. mm.
AspirationNatural
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 25 kVA Escorts Silent Diesel Generator
  • 25 kVA Escorts Silent Diesel Generator
  • 25 kVA Escorts Silent Diesel Generator
25 kVA Escorts Silent Diesel Generator

25 kVA Escorts Silent Diesel Generator

Rs 3.4 Lakh  / PieceGet Best Price

Product Brochure

Power Rarting25 KVA/20 KW
BrandEscorts
ApplicationIndustrial
Cooling SystemLiquid Cooling
Noise LevelSilent or Soundproof
Engine ModelG25-II
Dimension2400 x 1030 x 1410 mm (L x B x H)
Fuel Tank Capacity130 Liter
Rated Current108 Amp at 230 V, 35 Amp at 415 V
No Of Cylinders3
Dg Set ModelELG 25
Weight832 kg
Voltage415 V
Brake Horsepower37 BHP
AspirationTCIC
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 30 kVA Escorts Silent Diesel Generator
  • 30 kVA Escorts Silent Diesel Generator
  • 30 kVA Escorts Silent Diesel Generator
30 kVA Escorts Silent Diesel Generator

30 kVA Escorts Silent Diesel Generator

Rs 3.7 Lakh  / PieceGet Best Price

Product Brochure

Power Rating30 kVA
BrandEscorts
ApplicationIndustrial
Cooling SystemLiquid Cooling
Fuel TypeDiesel
Engine ModelG30-II
Dimension2400 x 1030 x 1410 mm (L x B x H)
Fuel Tank Capacity130 Liter
Rated Current130 Amp at 230 V, 42 Amp at 415 V
No Of Cylinders3
Dg Set ModelELG 30
Weight870 Kg
Voltage415 V
Brake Horsepower46 BHP
AspirationTCIC
Aluminium Cable2C-95/3.5C-35 Sq. mm.
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 35 kVA Escorts Silent Diesel Generator
  • 35 kVA Escorts Silent Diesel Generator
  • 35 kVA Escorts Silent Diesel Generator
35 kVA Escorts Silent Diesel Generator

35 kVA Escorts Silent Diesel Generator

Rs 3.95 Lakh  / PieceGet Best Price

Product Brochure

Power35 kVA
BrandEscorts
ApplicationIndustrial
Cooling SystemLiquid Cooling
Noise LevelSilent or Soundproof
Fuel typeDiesel
Engine ModelG40-II
Dimension2700 x 1030 x 1450 mm (L x B x H)
Capacity130 Liter
Rated Current152 Amp at 230 V, 49 Amp at 415 V
No Of Cylinders4
Dg Set ModelELG 35
Weight945 Kg
Voltage415 V
Brake Horsepower58 BHP
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:

  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 40 kVA Escorts Silent Diesel Generator
  • 40 kVA Escorts Silent Diesel Generator
  • 40 kVA Escorts Silent Diesel Generator
40 kVA Escorts Silent Diesel Generator

40 kVA Escorts Silent Diesel Generator

Rs 4.2 Lakh  / PieceGet Best Price

Product Brochure

Power Rating40 kVA
BrandEscorts
ApplicationIndustrial
Cooling SystemLiquid Cooling
Noise LevelSilent or Soundproof
Fuel typeDiesel
Engine ModelG40-II
Dimension2700 x 1030 x 1450 mm (L x B x H)
Fuel Tank Capacity130 Liter
Rated Current174 Amp at 230 V, 56 Amp at 415 V
No Of Cylinders4
Dg Set ModelELG 40
Weight1000 kg
Voltage415 V
Brake Horsepower58 BHP
AspirationTCIC
Aluminium Cable2C-120/3.5C-50 Sq. mm.
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 45 kVA Escorts Silent Diesel Generator
  • 45 kVA Escorts Silent Diesel Generator
  • 45 kVA Escorts Silent Diesel Generator
45 kVA Escorts Silent Diesel Generator

45 kVA Escorts Silent Diesel Generator

Rs 4.45 Lakh  / PieceGet Best Price
Power Rating45 kVA
BrandEscorts
MaterialMS
Usage/ApplicationIndustrial
Noise LevelSilent or Soundproof
Cooling SystemLiquid Cooling
Number Of Cylinder4
Voltage415 V
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back
  • 62.5 KVA Escorts Powerlux Silent Diesel Generator
  • 62.5 KVA Escorts Powerlux Silent Diesel Generator
  • 62.5 KVA Escorts Powerlux Silent Diesel Generator
62.5 KVA Escorts Powerlux Silent Diesel Generator

62.5 KVA Escorts Powerlux Silent Diesel Generator

Rs 5.6 Lakh  / PieceGet Best Price
Power62.5 kVA
Genset BrandPowerlux
Engine MakeEicher
Phase3 Phase
Cooling SystemLiquid Cooling
Noise LevelSilent or Soundproof
Frequency50 Hz
Fuel Tank Capacity130 Liter
Rated Current32 Amp at 230 V,10 Amp at 415 V
No Of Cylinders2
Voltage415 V
Other Essentials:
  • Engines are tested as per BS5514, IS: 10002 and IS01000B respectively. 
  • Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
  • Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E). 

How to Calculate Load: 
  • Put on only those equipment's which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
  • Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls. 

Note:
 
  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • AII of the above silent genset range is made to perform at 1500 rpm. 
  • Rated current output is at 100% load.(0.8 Power Factor). 
  • Weight mentioned is approximate. 
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice. 
  • Detailed technical specification sheet separately available for each rating in soft copy.

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES